| Heater voltage if heaters
in serie, V |
11.3 - 13.9 |
| Heater voltage if heaters
in parallel, V |
5.7 - 6.9 |
| Anode voltage, V: |
|
|
by anode dissipation > 30W |
250 |
|
by anode dissipation < 30W |
450 |
|
on switch-on |
600 |
| Grid voltage, V |
-0.5 to -150 |
| Cathode heater voltage,
V |
300 |
| Anode current, mA: |
|
|
using one cathode |
350 |
|
using two cathodes |
600 |
| Anode dissipation, W |
|
|
using one cathode |
45 |
|
using two cathodes |
60 |
| Resistance in grid circuit,
Mohm |
0.2 |
| Tube temperature, °C |
|
|
ambient temperature = 20 °C |
260 |
|
ambient temperature = 100 °C |
300 |
| Mechanical resistance: |
|
| Acceleration of vibration
loads by frequencies 10 to 250 Hz, g |
4 |
| Acceleration of multiple impacts,
g |
35 |
| Ambient temperature, °C |
-60 to +100 |